By the QuickSeq scientific team ยท Reviewed by Ronen Hope, PhD, Co-Founder & CSO ยท Updated October 2026 ยท All guides

Key takeaways

How the two methods differ

Sanger sequencing (capillary sequencing) reads one DNA region per reaction, starting from a primer you choose. The result is a chromatogram, a trace with one peak per base, and a single sequence of up to about 1,000 bases.

Next-generation sequencing (NGS) reads millions of DNA fragments in parallel and then puts them back together by alignment or assembly. Every position is read many times, which is what makes NGS sensitive and scalable.

SangerNGS short-read
(Illumina, Ultima)
NGS long-read
(PacBio HiFi, Nanopore)
OutputOne sequence per reactionMillions to billions of reads per runThousands to millions of long reads per run
Read length~700โ€“1,000 basesTypically 100โ€“300 basesThousands to over 100,000 bases
Read qualityQ40+ (โ‰ฅ99.99%) in the middle of a good read; lower at the start and endMost bases Q30+ (โ‰ฅ99.9%); quality drops toward the end of the readPacBio HiFi Q30+ per read; Nanopore about Q20 (~99%) per raw read, higher after consensus
Typical errorsMixed or noisy traces rather than random errorsMostly single-base substitutions (Ultima: mostly homopolymer length)Mostly small insertions or deletions, especially in homopolymers
Low-frequency variantsDetects down to ~15โ€“20%Detects down to ~1% with enough depthPossible, usually at lower depth than short reads
Mixed templatesOverlapping, unreadable tracesEach molecule read separatelyEach molecule read separately, end to end
StrengthsQuick checks of known targetsMany targets or samples, whole genomes, RNA-SeqWhole plasmids, long amplicons, structural variants, repeats, de novo assembly
Data analysisSimple: view the trace, align to a referenceNeeds a bioinformatics pipelineNeeds a bioinformatics pipeline

Read quality: what the numbers mean

Sequencing quality is usually given as a Phred score, written Q. Q20 means 1 error in 100 bases (99% accuracy), Q30 means 1 in 1,000 (99.9%) and Q40 means 1 in 10,000 (99.99%).

Two kinds of error behave differently. Random errors disappear as coverage goes up, because each position is read many times. Systematic errors, such as homopolymer length, can survive high coverage, so a critical base in such a region is worth confirming with a second method.

When Sanger is the right choice

In all of these you know what you expect to see, and a single clean read answers the question. You can send plasmids or PCR products in tubes or 96-well plates. GC-rich, repetitive or otherwise difficult templates may need a special reaction.

When NGS is the right choice

A quick decision guide

Your projectUsually the best fit
Check 5 clones for the right insertSanger
Verify the full sequence of a 7 kb plasmidWhole-plasmid long-read sequencing
Confirm one variant found by exome sequencingSanger
Screen 200 samples at 30 lociNGS targeted amplicon sequencing
Measure CRISPR editing efficiency in a cell poolNGS amplicon sequencing
Find the causal variant in a patient or a mutant lineWhole exome or whole genome sequencing
Profile a gut or soil microbial community16S amplicon or shotgun metagenomics

What about cost?

Sanger is priced per reaction, so it is the cheapest option for a handful of reads. NGS has a higher entry cost per run, but that cost is shared across every target and sample in the run. Once you multiply targets by samples into the hundreds, NGS almost always costs less per result. For a single plasmid, whole-plasmid long-read sequencing often costs less than the several Sanger reactions needed to walk across it.

QuickSeq shows an instant online estimate for Sanger and whole-plasmid sequencing. For NGS services, send us your project details and our team will reply with an estimate as soon as possible, so you can compare both routes before you decide.

Got your Sanger reads back? Check them against your reference with our free DNA Sequence Comparer. It runs in your browser and nothing is uploaded.

Frequently asked questions

Is Sanger sequencing more accurate than NGS?

For a single clean template, Sanger is extremely accurate (around 99.99% per base) and is often used to confirm variants. NGS reaches similar or better consensus accuracy by reading each position many times, and it can also detect variants that Sanger misses because they are present in only a small fraction of the DNA.

What is the lowest variant frequency Sanger can detect?

Roughly 15โ€“20% of the DNA in the sample. Below that, the second peak in the chromatogram is hard to distinguish from noise. Deep NGS can reliably detect variants down to about 1%, and lower with specialised methods.

How long a read do I get from Sanger sequencing?

Typically 700โ€“1,000 high-quality bases per reaction, depending on the template. Longer regions need several reactions with different primers (primer walking).

When does NGS become cheaper than Sanger?

When you multiply targets by samples. A few reactions are cheapest with Sanger; tens to hundreds of amplicons, or many samples at once, usually cost less per target with NGS amplicon sequencing.

Can I verify a whole plasmid without Sanger primer walking?

Yes. Whole-plasmid long-read sequencing reads the full circular plasmid in one go, with no primers needed. See our plasmid verification guide.

Know what you need?
Get an instant Sanger estimate online, or send us your NGS project for a quote. Not sure? Our scientists will help, free of charge.